Reliable and Clean Energy with Natural Gas Technology

KJ Power Natural Gas Generator


local_gas_station
Multi-Fuel Capability:
The KJR20 Ranger operates on natural gas, LPG, and gasoline, delivering uninterrupted power under any condition with fl exible fuel options.
settings
35 HP Vanguard Engine:
Equipped with a 35-horsepower Vanguard engine designed for high effi ciency and long life, ensuring maximum performance even in the most demanding fi eld conditions.
power_settings_new
PMG Alternator:
Features a PMG (Permanent Magnet Generator) alternator for high-quality and stable electrical output, providing safe energy for sensitive equipment.
speed
Variable Speed Operation & ECO Mode:
Offers variable speed operation via ECO mode, delivering benefi ts of fuel savings and reduced emissions, adapting to power demand.
volume_off
Quiet Operation:
Advanced insulation and horizontal engine technology ensure exceptionally low noise levels, enabling a comfortable and quiet working environment.
build
Lightweight Aluminum Chassis:
A lightweight and durable aluminum frame, a leader in its segment, allows for easy transport and long-lasting usage.
memory
Electronic Control System:
Modern electronic control system enables intelligent, safe operation and user-friendly management.
power
High-Quality Power Output:
Provides stable and high-quality electricity for a wide range of equipment and applications.
engineering
Low Maintenance:
Built for durability and reliability.
lightbulb
Innovative Solution:
Represents the future of efficient, mobile cold storage

Specifications


Technical Specifications Unit Values
Power Prime (kVA/kW) 18/14,4
Power Standby (kVA/kW) 20/16
Output Voltage (V) 400/231
Standby Current (cos φ=0,8)A 83
Prime Current (cos φ=0,8)A 91
Dimension w/o Canopy (LxWxH) (mm)
Dimension with Canopy (LxWxH) (mm) 823x678x780
Weight w/o Canopy (kg)
Weight with Canopy (kg) 180
Fuel Tank Capacity (l) -
Diesel Engine
Brand Vanguard
Model 6134
Speed (rpm) 1500
Total Displacement (l) 0,993
Number of Cylinders 2
Injection System Electronic Ignition
Governor Type Electronic
Intake Air Aspiration & Configuration Natural
Cooling System Air Cooled
Lub Oil Capacity (l) 2,3
Coolant Capacity (l) -
Fuel Consumption @ %100 load (l/h) -
Fuel Consumption @ %75 load (l/h) -
Fuel Consumption @ %50 load (l/h) -
Alternator
Frequency (Hz) 50
Steady State Voltage Regulation (Max) (+/-) ±0,5
Insulation Class (cos φ=0,8)A H
Protection Class IP 23
Power Factor 0,8

Natural Gas Generator vs Diesel Generator for Backup Power

Natural gas and diesel generators can both provide backup power, but their site dependencies are different. A natural gas generator can use a continuously supplied utility fuel where available, avoiding large on-site diesel storage and routine fuel polishing. A diesel generator stores its energy on site, which can provide independence from a gas network during a utility disruption if adequate fuel is available. Fuel cost, emissions, starting and load-step performance, maintenance, local permitting and outage scenarios should be compared for the specific project. For critical facilities, the reliability of the gas supply during the same event that causes a power outage is an important design question. The preferred technology therefore depends on the site's infrastructure and continuity strategy rather than fuel price alone.

Natural Gas Generator Fuel Consumption and Operating Costs

Natural gas generator fuel consumption depends on electrical load, engine efficiency and the energy content of the supplied gas. Because gas can be billed in different energy or volume units and its heating value can vary by network, a universal "per hour" consumption figure is not reliable across all projects. Operating cost should be calculated from the selected model's fuel-consumption data at relevant load points and the local gas tariff, then compared with expected annual operating hours. The analysis should also include standing charges, maintenance and any gas-pressure equipment needed at the site. For standby applications, annual fuel cost may be less important than supply reliability; for long-running applications, efficiency at the normal operating load becomes a major factor.

Natural Gas, LPG and Gasoline Multi-Fuel Generator Operation

A generator can operate on natural gas, LPG and gasoline only when its engine, fuel system and controls are specifically designed and approved for multi-fuel operation. Fuel properties, pressure, vaporisation, ignition requirements and control calibration are different, so fuels should not be substituted in a conventional single-fuel generator without manufacturer approval. KJ Power's current natural gas category includes a model described with multi-fuel capability, illustrating how this flexibility can be engineered into a product. For a project, confirm which fuels are approved, whether switching can occur during operation, the required regulators or tanks and whether the electrical rating changes between fuels. The operating manual and model-specific datasheet should govern fuel selection.

Natural Gas Generators for Standby and Continuous Power Applications

Natural gas generators can be configured for standby or longer-duration power duties, but the permitted operating regime is model-specific. Standby applications require reliable automatic starting and a fuel supply that remains available during the expected outage. Continuous or prime applications place greater importance on fuel pressure stability, thermal management, maintenance intervals and engine rating at the normal load. The project should distinguish between an emergency backup requirement and a generator that will act as a regular primary source. Engine and alternator ratings, ambient derating and the gas-supply system should all be checked for the intended duty. A generator described as natural gas powered is not automatically suitable for unlimited operation; the manufacturer's published rating and service instructions define the operating limits.

Natural Gas Supply Pressure and Installation Requirements for Generators

Natural gas generators require a fuel-supply system that can maintain the pressure and flow specified by the engine across the expected load range. Gas line sizing should consider distance, pipe pressure drop, regulator capacity, meter capacity and other consumers connected to the same supply. Isolation valves, emergency shutoff, ventilation and gas detection may also be required by local codes or project standards. A low-pressure event can reduce generator performance or cause shutdown even if the generator itself is correctly sized. For larger projects, coordination with the gas utility is important because the available network pressure and maximum flow may differ from the building's normal consumption. Final installation should follow the generator manufacturer, gas supplier and local authority requirements.

Natural Gas Generator Emissions and Environmental Performance

Natural gas combustion can reduce some pollutants associated with diesel fuel, particularly particulate matter and sulfur-related emissions, but environmental performance should be evaluated from the certified engine data rather than assumed. NOx and carbon monoxide remain important regulated pollutants, and greenhouse-gas assessment can also consider methane leakage or slip across the fuel supply and engine system. The result depends on engine technology, load, fuel composition and aftertreatment. For project comparison, use the applicable regional emission standard and model-specific certification data, then assess annual emissions using realistic operating hours. Noise, fuel infrastructure and local air-quality restrictions may also influence whether natural gas is the preferred solution for a commercial or industrial site.

How to Size a Natural Gas Generator for Your Power Requirements

Sizing a natural gas generator starts with the connected load, power factor, motor starting requirements and desired duty, just as with other generator technologies. Additional attention should be given to engine load-step capability and the gas-supply system because pressure or flow limitations can affect transient performance. The design should identify the largest motor starts, UPS or nonlinear loads, expected simultaneous demand and any future growth. Ambient temperature and altitude can also require derating. After selecting a candidate electrical rating, verify that the utility or on-site gas system can deliver the required fuel flow at the specified inlet pressure during maximum generator demand and while other gas consumers are operating.

Natural Gas Generators for Commercial, Industrial and Remote Applications

Natural gas generators can serve commercial buildings, industrial facilities and remote applications when an appropriate fuel source is available. In commercial sites, they may provide standby power without maintaining a large diesel inventory. Industrial projects can use gas generation where operating hours are higher and fuel economics support it. Remote sites may use pipeline gas, LPG or another approved fuel configuration depending on the equipment and logistics. The application should define whether the generator is for emergency backup, prime power or a specialised mobile use case. Fuel availability, electrical load, emission requirements, service capability and outage risk should all be evaluated together. Where multi-fuel operation is required, the exact approved fuels and ratings should be confirmed from the selected model rather than generalised across the category.

Natural Gas Generator Frequently Asked Questions

Hourly natural gas use depends on generator output, load percentage, engine efficiency and the heating value of the gas. The reliable method is to use the selected model's fuel-consumption curve at the expected load and convert it using the local gas energy content and billing unit. A generic volume-per-hour figure can be misleading because both generator size and gas quality vary.

A natural gas generator can support long-duration operation if the specific engine is rated for that duty, the gas supply remains stable and required maintenance is performed. The project must distinguish standby, prime and continuous ratings. Around-the-clock operation also requires planning for service intervals, cooling, oil consumption and a fuel system that can maintain pressure and flow at full demand.

The main difference is the fuel and its infrastructure. A natural gas generator normally depends on a gas network or approved gaseous-fuel supply, while a diesel generator stores liquid fuel on site. This affects fuel logistics, outage resilience, emissions, maintenance and operating cost. Electrical sizing principles are similar, but engine response and fuel-system requirements should be checked for the chosen technology.

Only if the generator is specifically designed and approved for those fuels. Multi-fuel engines use fuel controls and calibration that accommodate different gaseous or liquid fuels. KJ Power's current category includes a model with natural gas, LPG and gasoline capability, but that should not be assumed for every natural gas generator. Always follow the selected model's approved-fuel list and operating instructions.

Not necessarily. A generator connected to a reliable natural gas utility can receive fuel through the gas line, so a liquid-style fuel storage tank is not required for that operating mode. LPG or other stored gaseous fuels may require approved tanks and vapour or pressure-control equipment. The fuel arrangement depends on the selected fuel, utility availability and local safety requirements.

If gas pressure or flow falls below the engine's required range, the generator may derate, run poorly or shut down depending on its controls and fuel system. For critical backup applications, the project should assess whether the gas supply is likely to remain available during the same emergency that causes the electrical outage. Where that risk is unacceptable, alternative or multi-fuel strategies may be considered if approved by the equipment design.

Here for You!
Getting in touch with us has never been easier!
Not empty.
Not empty.
Not empty.
Select country.
Select country.
Not empty.
Subscribe to our newsletter

By subscribing to our newsletter, you'll be the first to receive information about our new products, promotions, and industry developments. By subscribing, you acknowledge that you have read and accepted the Personal Data Protection Law (KVKK)


Kj Power

KJ Power is a well-established diesel generator manufacturer operating in the energy sector since 1996. The company, which produces a wide range of diesel generator sets from 10 kVA to 5000 kVA, has international ISO 9001:2015 and other important certificates. As a generator company, it provides special generators for projects by offering special engineering solutions. Serving many sectors in Turkey, KJ Power has proven its global success as a generator manufacturer by exporting 90% of its production to more than 120 countries.

Jender Egsa